Download or view technical
documents for the listed products. Click on the product's image to view an
enlargement. For help downloading the pdf files, please click on the "PDF
help" icon. |
|
|
Page 1
|
Page 2
|
Page 3
|
Page 4
|
Page 5
|
|
|
| Applications: |
For liquids only. Ideal for dirty fluids, has high tolerance to solids
(up to 15%) and immune to viscosities to 400 cP. Mounts in any direction to measure flow
in vertical (up/down) or horizontal pipe lines.
|
| Flow Range: |
0.8 m3/h to 1 600 m3/h |
| Accuracy: |
|
| Connection: |
| DP-65: |
DN40 to DN300 sandwich |
| DP-500: |
DN250 to DN500 flange (DIN, ANSI or others) |
|
| Scale: |
10:1 |
| Materials: |
Polyamide coated steel (Standard), SS-316L |
| Temperature: |
-160șC to +130/180șC |
| Pressure: |
10 to 40 bar |
| Alarms: |
Magnetic actuated micro switch, Inductive proximity switch
|
| Transmitter: |
4-20mA, 4-20mA + totaliser, 4-20mA (EEx ia IIC T4), 4-20mA (EEx ia IIC T6), 3-15 psi |
DP-65.pdf (216 kB)
|
|
|
| Applications: |
Flow indication of liquids and gases. Can be mounted vertically or horizontally.
|
| Flow Range: |
15 l/h to 16 000 l/h (Water) 180 Nl/h to 240 Nm3/h (Air) |
| Accuracy: |
±6% FS |
| Connection: |
1/4" to 2 1/2" BSP |
| Scale: |
10:1 |
| Materials: |
Brass, SS-316L |
| Temperature: |
-10șC to +120șC |
| Pressure: |
10 to 20 bar |
| Alarms: |
Reed switch |
| Transmitter: |
4-20mA (ADT-15 only) |
AD-15.pdf (??? kB)
|
|
|
| Applications: |
Digital flow switch.
|
| Flow Range: |
30 m3/h to 1 000 m3/h (Water) 100 Nm3/h to 30 000 Nm3/h (Air) |
| Accuracy: |
±6% |
| Connection: |
1" BSP, NPT |
| Materials: |
SS-316L, PVC, PTFE, Hastelloy |
| Temperature: |
-40șC to +125șC |
| Pressure: |
10 to 25 bar |
| Length: |
100 to 540 mm |
| Output: |
Reed switch, SPDT, 0.5A, 48Vac, 3VA |
VH-35.pdf (??? kB)
|
|
TOP
|
Page 1
|
Page 2
|
Page 3
|
Page 4
|
Page 5
|
|