  Tecfluid Catalog  

Full Tecfluid Catalog:  2003 catalog.pdf (2,939 kB)  


LC30 Multi-Point Level Switch 
LC30  
Applications: A multi point level switch for liquids. The reed switches are bistable (i.e. the switch indicates whether the float is above or below it.
Length: 100 to 6 000 mm
Materials: SS-316L, PVC, PTFE
Connection: 1 1/2" BSP threaded or DN40 DIN flange
Output: Bistable Reed Switch, 1 to 6 points
Accuracy: ±5 mm 
Pressure: 16 to 100 bar
Temperature: -40șC to +150șC
Viscosity: up to 1 500 mPa.s
Density: 0.45 to 3 kg/l

 LC-30.pdf (86 kB)  


LC-40 Fixed Point Level Switch 
LC-40  
Applications: A point level measurement switch which uses magnetic coupling to activate a micro switch. This means that no seal is required between the process and the instrumentation.
Length: 52 to 1 100 mm
Materials: SS-316L, PVC, PTFE
Connection: DN65 DIN flange
Output: Micro Switch, Reed Switch or Pneumatic Switch
Accuracy: ±3 mm 
Pressure: 16 to 400 bar
Temperature: -40șC to +150șC  / 300șC with high temperature sensor
Viscosity: up to 3 000 mPa.s

 LC-40.pdf (150 kB)  


LD-60 Tuning Fork Level Detector
LD-60  
Applications: A point level switch which monitors resonant frequency for switching
Length: 130 to 6 000 mm
Materials: SS-316L, Hastelloy C and others on request
Connection: G 1" BSP threaded, 1" NPT threaded, DN32 DIN flange, 1 1/4" ANSI flange, JIS flange
Accuracy: ±2 mm 
Accuracy: ±3 mm 
Pressure: 16 bar (threaded connection), PN16 to PN 100 (flange connection), up to 400 bar on request
Temperature: -40șC to +115șC, 150șC on request

LT-10 Level Gauge & Transmitter 
LT-10  
Applications: Liquid level measurement with alarm and transmitter outputs. Full process isolation.
Length: 300 to 15 000 mm
Materials: SS-316L, PVC, PTFE, PP, PVDF
Connection: 1 1/2" BSP threaded or DN20 toDN40 DIN flange
Output:
Alarm: 1 to 2 magnetic actuated micro switch / 1 to 2 inductive proximity sensor / 1 to 2 magnetic actuated reed switch (EEx d housing available)
Transmitter: 4-20mA, others also available
Accuracy: ±3.5 mm 
Pressure: 16 to 400 bar
Temperature: -60șC to +400șC
Viscosity: up to 1 500 mPa.s
Density: 0.45 to 3 kg/l

 LT-10.pdf (199 kB)  


LP-80 Level Indicator & Transmitter 
LP-80  
Applications: Liquid level measurement with alarm and transmitter outputs. Uses magnetic coupling for indication.
Length: 300 to 6 000 mm
Materials: SS-316L, PVC, PTFE
Connection: 1 1/2" BSP threaded or DN40 DIN flange
Output:
Alarm: 1 to 2 magnetic actuated micro switch / 1 to 2 inductive proximity sensor
Transmitter: 4-20mA, 4-20mA (EEx ia IIC T4), 4-20mA (EEx ia IIC T6), 3-15 psi
Accuracy: ±1.5% 
Pressure: 16 to 320 bar
Temperature: -60șC to +400șC
Viscosity: up to 200 mPa.s
Density: 0.5 to 2 kg/l

 LP-80.pdf (108 kB)  


LE70 Level Transmitter 
LE70  
Applications: An analogue level transmitter for liquids.
Length: 100 to 6 000 mm
Materials: SS-316L, PVC, PTFE
Connection: 1 1/2" BSP threaded or DN40 DIN flange
Output: 0...4-20mA, 0...1-5V, 0...2-10V
Accuracy: ±5 mm 
Pressure: 16 to 100 bar
Temperature: -20șC to +120șC
Viscosity: up to 1 500 mPa.s
Density: 0.45 to 3 kg/l