| Applications: |
The PB Series of pressure transmitters are used to determine the pressure in liquids and gases and convert these pressures
into an electrical signal. They feature compact construction, an integral amplifier, large output signal and extensive
media compatibility.
The PB Series pressure transmitter can be extensively applied in petroleum, chemical industry, metallurgy, power generation,
medicine, refrigeration, mining, level and compressors.
|
| Technical Data: |
| Range: |
-100 kPa to 0, 0 to 10 kPa ... 40 MPa (400 bar) |
| Accuracy: |
0.25% |
| Linearity: |
0.2% of full scale |
| Thermal Stability: |
<±0.025% of full scale per °C |
| Long Term Stability: |
<0.2% of full scale per annum |
| Overload Limit: |
150% |
| Response Time: |
10 milli seconds |
| Output: |
4 - 20 mA (24 Vdc) two wire |
| Medium Temperature: |
-20°C to +85°C |
| Storage Temperature: |
-40°C to +125°C |
| Housing: |
IP65 and EEx |
| Displays: |
Blind / Analogue / LED / LCD |
| Diaphragm: |
316 Stainless Steel |
| Pressure Connection: |
M20 x 1.5 or ½" NPT |
| Electrical Connection: |
M20 x 1.5 |
| Operating Position: |
Unrestricted |
|
|
|
|
| Technical Data: |
| Range: |
-100 kPa to 0, 0 to 10 kPa ... 6 MPa (60 bar) |
| Accuracy: |
0.25% |
| Linearity: |
0.2% of full scale |
| Thermal Stability: |
<±0.025% of full scale per °C |
| Long Term Stability: |
<0.2% of full scale per annum |
| Overload Limit: |
150% |
| Response Time: |
10 milli seconds |
| Output: |
4 - 20 mA (24 Vdc) two wire |
| Medium Temperature: |
-20°C to +85°C |
| Storage Temperature: |
-40°C to +125°C |
| Housing: |
IP65 |
| Displays: |
Blind |
| Diaphragm: |
316 Stainless Steel |
| Pressure Connection: |
M20 x 1.5 or ½" NPT |
| Electrical Connection: |
M20 x 1.5 |
| Operating Position: |
Unrestricted |
|
|
|
|
| Technical Data |
| Range: |
-100 kPa to 0, 0 to 10 kPa ... 6 MPa (60 bar) |
| Accuracy: |
0.25% |
| Linearity: |
0.2% of full scale |
| Thermal Stability: |
<±0.025% of full scale per °C |
| Long Term Stability: |
<0.2% of full scale per annum |
| Overload Limit: |
150% |
| Response Time: |
10 milli seconds |
| Output: |
4 - 20 mA (24 Vdc) two wire |
| Medium Temperature: |
-30°C to +120°C |
| Storage Temperature: |
-40°C to +125°C |
| Housing: |
IP65 |
| Displays: |
Blind |
| Diaphragm: |
316 Stainless Steel |
| Pressure Connection: |
M20 x 1.5 or ½" NPT |
| Electrical Connection: |
M20 x 1.5 |
| Operating Position: |
Unrestricted |
|
|
|
|
| Applications: |
The HG Series of pressure transmitters are used to determine the pressure in liquids and gases and convert these pressures
into an electrical signal. They feature compact construction, an integral amplifier, large output signal and extensive
media compatibility.
The PB Series pressure transmitter can be extensively applied in petroleum, chemical industry, metallurgy, power generation,
medicine, refrigeration, mining where differential pressure measurement is desirable.
|
| Technical Data |
| Range: |
-100 kPa to 0, 0 to 10 kPa ... 40 MPa (400 bar) |
| Accuracy: |
0.25% |
| Linearity: |
0.2% of full scale |
| Thermal Stability: |
<±0.025% of full scale per °C |
| Long Term Stability: |
<0.2% of full scale per annum |
| Overload Limit: |
150% |
| Response Time: |
10 milli seconds |
| Output: |
4 - 20 mA (24 Vdc) two wire |
| Medium Temperature: |
-20°C to +85°C |
| Storage Temperature: |
-40°C to +125°C |
| Housing: |
IP65 and EEx |
| Displays: |
Blind / LCD |
| Diaphragm: |
316 Stainless Steel |
| Pressure Connection: |
M20 x 1.5 or ½" NPT |
| Electrical Connection: |
M20 x 1.5 |
| Operating Position: |
Unrestricted |
|
|
|